Products
Wide Variety of Products
-
- Utilizes forced system to provide greater efficiency and better air flow.
- Three and four tube passes which provide greater heat transfer.
- High thermal wear levels.
- Inexpensive maintenance.
- Ease of Installation.
- Easy Maintenance
- EnvironmentFriendly
- Premium Service
- Advanced BMS.
Technical Information
1 | Orientation | Horizontal |
2 | Manufacturing Codes | ASME Or Eqv. |
3 | Capacity | 1 TPH – 25 TPH |
4 | Pressure | UPTO 60 Bar(g) |
5 | Typical Efficiency | Upto 92% |
6 | Burning Mode | Gas/Diesel/HFO/LDO |
- Increase in efficiency and environmental responsibility through use of waste heat.
- Matched, modular system for easy planning and fast Installation.
- Highest efficiency gain thanks to Solarkaz integrated economizers.
- Intuitive boiler control based on PLC with the highest level of operating.
- data transparency.
- Simple commissioning due to per-parameterized boiler control.
- Easy wiring on site thanks to plug-in connections Robust, reliable and durable.
- Reduced component diversity with regard to availability of spare parts.
- Minimum Pressure Drop/Back Pressure throughout the system.
Technical Information
1 | Orientation | Horizontal / Vertical |
2 | Manufacturing Codes | ASME Or Eqv. |
3 | Capacity | 0.5 TPH – 17 TPH |
4 | Pressure | UPTO 60 bar(g) |
5 | Typical Efficiency | Up to 92% |
- Safety and reliable.
- Huge combustion chamber.
- Space flexibility of various fuels.
- Flue gas emission meets the national code re
- Robust design provides agile adjusting stable combustion bed and reliable operation.
- Boiler use full automatic control system and it could achieve automatic fuel feeding, water/ thermic oil feeding, bed functioning, and fan auto operation.
- Boiler drum larger water content strengthens the adjustability of boiler steam output capacity.
- For thermal oil heaters control system provide automatic and manual type controlling for supervision and protection, regulating & adjusting the temperature in high accurate. Alarm and protecting in overheating, oil shortage, Low pressure or high pressure etc.
- Technical Information
1 Orientation Horizontal / Vertical 2 Manufacturing Codes ASME Or Eqv. 3 Capacity for thermic oil 1.5 MKCal – 10 MKCal 4 Capacity for Steam 2 TPH – 25 TPH 5 Pressure UPTO 60 Bar(g) 6 Typical Efficiency Up to 89% 7 Fuel Coal/Wood/Bagasse/Biomass etc.
- High operating temperatures – up to 300 ͦC at atmospheric pressure.
- Adjustable set-points of operating temperatures.
- Better operation economy. Quiet in operation.
- Acceptance and erection obligations. Expensive water treatment.
Technical Information
1 | Orientation | Horizontal / Vertical |
2 | Manufacturing Codes | ASME Or Eqv. |
3 | Capacity | 1.5 MKCal – 10 MKCal |
4 | Pressure | As Required |
5 | Typical Efficiency | Upto 92% |
6 | Burning Mode | Gas/Diesel/HFO/Solid Fuel |
Solarkaz International established as an Industrial Solutions Company. Our broad range of skills and capabilities allow Solarkaz International to serve a diverse group of customers that provide products worldwide. We take pride in knowing that by using Solarkaz International pressure vessels in their operations our customers provide goods and services that impact lives everywhere. Solarkaz International provides stainless pressure vessels to various industries, such as:-
- Beverage
- Pharmaceuticals
- Water and Waste Water. Oil, Gas and Ethanol.
- Health, Personal Care and Cosmetics. Chemical.
- Food and Dairy.
.
Durability – Built in accordance with ASME Code, our Shell and Tube Heat Exchangers are designed to withstand the rigid conditions of Industries. Our heat exchangers are known to last much longer than other shell and tube heat exchangers.
Quality (ASME U STAMP)– Solarkaz International is a synonym to quality, which is why we use the best and top quality material available in the market for our products. Each and every unit at Solarkaz International is tested and inspected carefully. Design Shell and Tube Heat exchangers at Solarkaz International are specifically designed using modern techniques, most modern technology and accurate construction material.
Efficiency– Solarkaz International has designed its Shell and Tube Heat exchangers to be one of the most efficient ones available in the industry.
Technical Information:
1 | Type | Shell & Tube type |
2 | Manufacturing Codes | ASME Or Eqv. |
3 | Range | 100 Sq. ft – 10,000 Sq. ft. |
4 | Pressure | UPTO 200 Bar(g) |
5 | Typical Efficiency | Upto 92% |
Solarkaz International established as an Industrial Solutions Company. Our broad range of skills and capabilities allow Solarkaz International to serve a diverse group of customers that provide products worldwide. We take pride in knowing that by using Solarkaz International tanks in their operations our customers provide goods and services that impact lives everywhere. Solarkaz International provides stainless steel tanks to various industries, such as:-
- Beverage
- Pharmaceuticals
- Water and Waste Water. Oil, Gas and Ethanol.
- Health, Personal Care and Cosmetics.
- Food and Dairy.
.
Product Code: SK-034 (Acid Inhibitor)
A unique organic corrosion inhibitor, specially developed to inhibit the corrosion in acidic media by lowering the reaction rate of acid with metal and by providing a very thick blanketing of the metal surfaces.
SK-034 immediately decreases the acid attack on the metal without appreciably altering the rate of scale removal.
SK-034 provide excellent result of metal protection during acid cleaning of Boilers, Evaporators, Boiling Column & Condenser.
Product Code: SK-028 (Hardness Controller + Antiscalant)
It most effective formulation, blended with sodium salts, polymer and organic sludge conditioners, so that sodium salts form very soluble complexes with the hardness salts, and are stable at high temperature, polymer provide dispersion and sludge conditioners to enhance their effectiveness.
Product Code: SK-016 (Volatile Oxygen Scavenger)
A top class oxygen scavenger employs organically catalized hydrazine, SK-016 reactions are inert and do not add to dissolved solids in boiler water, makes its use extremely desirable in those systems in which T.D.S in boiler water constitute the limiting factor for boiler blow down being a powerful reducing agent.
SK-016 transforms iron and copper to its most stable oxides, resulting in uniform passivation of the metal surfaces and increases protection.
Product Code: SK-019 (Oxygen Scavenger)
It is a most efficient corrosion inhibitor employs activated sodium sulphate of pure grade. It reacts readily with oxygen particularly at elevated pH and temperature to form sodium sulfate.
It is specially formulated for food and pharmaceutical plans SK-019 is recommended for low and moderate pressure boilers.
Product Code: SK-013 (Sludge Conditioner + Anti Foam)
A Unique blend of various most effcient sludge conditioning and antifoaming agents specially formulated to suit a wide variety of steam generators.
It employs orthophosphate based precipitating programe supplemented by patented polymers for better sludge conditioning, which also promotes metal dispersion and distoration of crystalline growth within the boiler. Antifoam increases surface tension, frequently reduces steam by preventing carryover.
Product Code | SK-034 | SK-028 | SK-016 | SK-019 | SK-013 |
Type | Acid Inhibitor | Hardness Controller + Antiscalant | Volatile Oxygen Scavenger | Oxygen Scavenger | Sludge Conditioner + Anti Foam |
Colour | Pale Yellow | Dark Brown | Colourless | Dark Brown | Dark Brown |
pH | 4.5 | 12 | 12 | 12 | 12 |
Odour | Slight | Slight | Ammonic | Slight | Slight |
Fr. Point | -60°C | <-5°C | -6°C | <-5°C | |
Sp. Gravity | 1.005 @25°C | 1.20 Kg/Ltr | 1.30 Kg/Ltr | 1.20 Kg/Ltr | 1.30 Kg/Ltr |
Bo. Point | 98°C | 101°C | 101°C | 101°C | 101°C |
Dosage : | To achive 100% metal protection SK-034 should be added to the rate of 2% and | SK-019 feed continuously to feed water can be used with any catalized oxygen Scavenger and neutralizing amine. The quantity of SK-028 will very according to the feed water hardness. | SK-016 feed continuously into the system to be treated. The quantity of SK-016 can be determined by simple analytical procedure available with your local agent. Normally a small residual concentration of SK-016 is to be maintained in the system water. | SK-019 feed continuously into the system to be treated normally 30-45 ppm, SK-019 concentration is to be maintained in system water. | SK-013 feed continuously to feed water. Softened makeup water is recommended, can be sued with any catalized oxygen scavenger and neutralizing amine. The quantity of SK-013 will vary according to the feed water hardness. |
Packaging : | SK-034 is supplied in 35 kgs. non-returnable drums. | SK-028 is supplied in 35 kgs. non-returnable drums. | SK-016 is supplied in 35 kgs. non-returnable drums. | SK-019 is supplied in 35 kgs. non-returnable drums. | SK-013 is supp lied in 35 kgs. non-returnable drums. |
Note :
The above results can serve only as guide and are therefore offered without guarantee.
Ready to Connect With Us?
We offer you the best boiler technology, features and support.